Extreme summit x440-24p PoE 에러 처리

Extreme summit x440-24p PoE 에러 처리

CCTV 카메라 연결된 스위치에서 아래처럼 PoE 오류 발생
아래에서, short 된 포트는 3, 8번은 faulted 상태로, overcurrent 발생한 포트는 denied 상태가된 것을 볼 수 있다.

switch # show inline-power stats port 1-24

                                STATISTICS COUNTERS
Port  State         Class     Absent  InvSig   Denied    OverCurrent   Short
1     denied        ------        0       0       0          1             0
2     denied        ------        0       0       0          1             0
3     faulted       ------        0       0       0          0             1
4     searching     ------        0     101       0          0             0
5     denied        ------        0       0       0          1             0
6     denied        ------        0       0       0          1             0
7     denied        ------        0       0       0          1             0
8     faulted       ------        0       0       0          0             1
9     denied        ------        0       0       0          1             0
10    denied        ------        0       0       0          1             0
11    denied        ------        0       0       0          1             0
12    denied        ------        0       0       0          1             0
13    denied        ------        0       0       0          1             0
14    denied        ------        0       0       0          1             0
15    denied        ------        0       0       0          1             0
16    denied        ------        0       0       0          1             0
17    searching     ------        0      78       0          0             0
18    searching     ------        0      78       0          0             0
19    searching     ------        0      77       0          0             0
20    searching     ------        0      77       0          0             0
21    searching     ------        0     107       0          0             0
22    searching     ------        0     107       0          0             0
23    searching     ------        0     107       0          0             0
24    searching     ------        0     107       0          0             0

로그를 확인해 보면 아래와 같다.

10/27/2018 16:21:26.00 <Warn:POE.power_denied> Port 16 was denied power
10/27/2018 16:21:25.89 <Warn:POE.power_denied> Port 15 was denied power
10/27/2018 16:21:25.79 <Warn:POE.power_denied> Port 14 was denied power
10/27/2018 16:21:25.70 <Warn:POE.power_denied> Port 13 was denied power
10/27/2018 16:21:25.29 <Warn:POE.power_denied> Port 12 was denied power
10/27/2018 16:21:25.19 <Warn:POE.power_denied> Port 11 was denied power
10/27/2018 16:21:25.10 <Warn:POE.power_denied> Port 10 was denied power
10/27/2018 16:21:25.00 <Warn:POE.power_denied> Port 9 was denied power
10/27/2018 16:21:24.89 <Erro:POE.port_fault> Port 8 has encountered a fault condition
10/27/2018 16:21:24.80 <Warn:POE.power_denied> Port 7 was denied power
10/27/2018 16:21:24.71 <Warn:POE.power_denied> Port 6 was denied power
10/27/2018 16:21:24.68 <Info:vlan.msgs.portLinkStateDown> Port 16 link down
10/27/2018 16:21:24.66 <Info:vlan.msgs.portLinkStateDown> Port 15 link down
10/27/2018 16:21:24.66 <Info:vlan.msgs.portLinkStateDown> Port 14 link down
10/27/2018 16:21:24.61 <Info:vlan.msgs.portLinkStateDown> Port 13 link down
10/27/2018 16:21:24.57 <Info:vlan.msgs.portLinkStateDown> Port 12 link down
10/27/2018 16:21:24.54 <Info:vlan.msgs.portLinkStateDown> Port 11 link down
10/27/2018 16:21:24.52 <Warn:POE.power_denied> Port 5 was denied power
10/27/2018 16:21:24.50 <Info:vlan.msgs.portLinkStateDown> Port 10 link down
10/27/2018 16:21:24.47 <Info:vlan.msgs.portLinkStateDown> Port 9 link down
10/27/2018 16:21:24.44 <Info:vlan.msgs.portLinkStateDown> Port 8 link down
10/27/2018 16:21:24.41 <Info:vlan.msgs.portLinkStateDown> Port 7 link down
10/27/2018 16:21:24.39 <Erro:POE.port_fault> Port 3 has encountered a fault condition
10/27/2018 16:21:24.37 <Info:vlan.msgs.portLinkStateDown> Port 6 link down
10/27/2018 16:21:24.35 <Info:vlan.msgs.portLinkStateDown> Port 5 link down
10/27/2018 16:21:24.33 <Info:vlan.msgs.portLinkStateDown> Port 3 link down
10/27/2018 16:21:24.31 <Info:vlan.msgs.portLinkStateDown> Port 2 link down
10/27/2018 16:21:24.29 <Info:vlan.msgs.portLinkStateDown> Port 1 link down
10/27/2018 16:21:24.28 <Warn:POE.power_denied> Port 2 was denied power
10/27/2018 16:21:24.19 <Warn:POE.power_denied> Port 1 was denied power

inline power를 끄고 상태 확인해 본다.

Switch.4 # disable inline-power ports 1-24
* Switch.5 # show inline-power stats ports 1-24

                                STATISTICS COUNTERS
Port  State         Class     Absent  InvSig   Denied    OverCurrent   Short
1     disabled      ------        0       0       0          1             0
2     disabled      ------        0       0       0          1             0
3     disabled      ------        0       0       0          0             1
4     disabled      ------        0     155       0          0             0
5     disabled      ------        0       0       0          1             0
6     disabled      ------        0       0       0          1             0
7     disabled      ------        0       0       0          1             0
8     disabled      ------        0       0       0          0             1
9     disabled      ------        0       0       0          1             0
10    disabled      ------        0       0       0          1             0
11    disabled      ------        0       0       0          1             0
12    disabled      ------        0       0       0          1             0
13    disabled      ------        0       0       0          1             0
14    disabled      ------        0       0       0          1             0
15    disabled      ------        0       0       0          1             0
16    disabled      ------        0       0       0          1             0
17    disabled      ------        0     131       0          0             0
18    disabled      ------        0     130       0          0             0
19    disabled      ------        0     130       0          0             0
20    disabled      ------        0     129       0          0             0
21    disabled      ------        0     160       0          0             0
22    disabled      ------        0     159       0          0             0
23    disabled      ------        0     159       0          0             0
24    disabled      ------        0     158       0          0             0

inline power를 다시 공급하고 상태를 확인 해 보면 정상적으로 power가 공급됨을 확인 할 수 있다.

* Switch.6 # enable inline-power ports 1-24
* Switch.7 # show inline-power stats ports 1-24

                                STATISTICS COUNTERS
Port  State         Class     Absent  InvSig   Denied    OverCurrent   Short
1     delivering    class3        0       0       0          1             0
2     delivering    class3        0       0       0          1             0
3     delivering    class4        0       0       0          0             1
4     searching     ------        0     160       0          0             0
5     delivering    class3        0       0       0          1             0
6     delivering    class3        0       0       0          1             0
7     delivering    class3        0       0       0          1             0
8     delivering    class4        0       0       0          0             1
9     delivering    class3        0       0       0          1             0
10    delivering    class3        0       0       0          1             0
11    delivering    class3        0       0       0          1             0
12    delivering    class3        0       0       0          1             0
13    delivering    class3        0       0       0          1             0
14    delivering    class3        0       0       0          1             0
15    delivering    class3        0       0       0          1             0
16    delivering    class3        0       0       0          1             0
17    searching     ------        0     140       0          0             0
18    searching     ------        0     139       0          0             0
19    searching     ------        0     140       0          0             0
20    searching     ------        0     139       0          0             0
21    searching     ------        0     170       0          0             0
22    searching     ------        0     170       0          0             0
23    searching     ------        0     170       0          0             0
24    searching     ------        0     169       0          0             0

이제, 포트별 inline power의 카운터를 초기화하고 나중에 오류가 발생 할 경우 확인 할 수 있도록 한다.

* Switch.3 # clear inline-power stats port all

* Switch.5 # sh inline-power st ports 1-24

                                STATISTICS COUNTERS
Port  State         Class     Absent  InvSig   Denied    OverCurrent   Short
1     delivering    class3        0       0       0          0             0
2     delivering    class3        0       0       0          0             0
3     delivering    class4        0       0       0          0             0
4     searching     ------        0      28       0          0             0
5     delivering    class3        0       0       0          0             0
6     delivering    class3        0       0       0          0             0
7     delivering    class3        0       0       0          0             0
8     delivering    class4        0       0       0          0             0
9     delivering    class3        0       0       0          0             0
10    delivering    class3        0       0       0          0             0
11    delivering    class3        0       0       0          0             0
12    delivering    class3        0       0       0          0             0
13    delivering    class3        0       0       0          0             0
14    delivering    class3        0       0       0          0             0
15    delivering    class3        0       0       0          0             0
16    delivering    class3        0       0       0          0             0
17    searching     ------        0      33       0          0             0
18    searching     ------        0      33       0          0             0
19    searching     ------        0      33       0          0             0
20    searching     ------        0      33       0          0             0
21    searching     ------        0      34       0          0             0
22    searching     ------        0      35       0          0             0
23    searching     ------        0      35       0          0             0
24    searching     ------        0      35       0          0             0

답글 남기기